Metal case IP 44 protection level
Protections:short circuit/over load/over voltage/over temp
100%full load test.
Apply to out-door LED lighting and signboard application
2 years warranty
Technical data:
Model |
FS-400-12 |
FS-400-15 |
FS-400-24 |
FS-400-36 |
FS-400-48 |
|
output |
DC voltage |
12V |
15V |
24V |
36V |
48V |
Voltage tolerance |
±1% |
±1% |
±1% |
±1% |
±1% |
|
Rated current |
33A |
27A |
16.5A |
11 |
8.3 |
|
Current range |
0~33A |
0~27A |
0~16.5A |
0~11A |
0~8.3A |
|
Rated power |
396W |
405W |
396W |
396W |
398.4W |
|
Ripple &noise |
150mvp-p |
150mvp-p |
200mvp-p |
200mvp-p |
200mvp-p |
|
adjustable DC voltage range |
±10% |
±10% |
±10% |
±10% |
±10% |
|
input |
Voltage range |
180~264VAC,255~373VDC |
||||
frequency |
47~63HZ |
|||||
AC current |
4.0A/230VAC |
|||||
efficiency |
82% |
82% |
84% |
85% |
86% |
|
Inrush current |
Cold start current 50A/230VAC |
|||||
Leakage current |
< 3.5mA/240VAC |
|||||
protection |
overload |
Rated output power105%~135% start over load protection |
||||
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||
over voltage |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
42.6~44.2V |
54.8~56.6V |
|
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||
over temperature |
TSW1detect on heatsink of power transistor≥85°C±5°C, start over temperature protection |
|||||
protection type:hiccup mode,auto-recovery after temperature become normal |
||||||
environment |
Working temp, humidity |
-10°C~+60°C,20%~90%RH |
||||
Storage temp, humidity |
-20°C~+85°C,10%~95%RH non-condensing |
|||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
|||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
|||||
standard |
Safety standard |
Fit UL1012 IP44 |
||||
EMC standard |
EN55022,CLASSA |
|||||
others |
Dimension |
236*135*65mm (L*W*H) |
||||
Weight/packing |
1.4kg/12pcs/17.5kg/0.039m³/1.36CUFT |
|||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |